Reliable performance for many years
depends on consistent and proper maintenance of the SDI system. Routine and preventive
maintenance
is critical.
Operating pressure: keep the right pressure in the system, according to
design. Stop irrigation if pressure in the water supply system drops below
the required minimum.
Clean the filters when pressure difference between inlet and outlet of
the filter is above 5 m. Inspect carefully the filter element at least
once a month.
Laterals flushing: flushing frequency based on the water quality;
once a month (clear water), once every two weeks (dirty water),
every irrigation (very dirty water). The flushing must be in high pressure
therefore, the collectors should be flushed one after another. Flush
during the irrigation without fertilizers.
Flow rates inspection: if the flow rate is higher than the primary
value, search for bursts in the system and/or blocked emitters. If the
flow rate is lower than the primary value, check pressure in the system
and/or search for blocked emitters.
Air & Vacuum valves: check valves at the start of every season and at
least once during the season.
Non-return valves: inspect non-return property of the valve before
every chemical/fertilizer injection.
Root intrusion prevention: maintain an irrigation regime that minimises
moisture stress. Inject Treflan time to time.
Acidification and chlorination: water source quality and contaminants
will dictate treatment and frequency. In reasonably clean water three
treatments per season are recommended. |